Fire prevention regulations in warehouses producing shelves

nha-may-san-xuat-ke-sieu-thi-2

VietPOSRack tells you the secret to building warehouse and factory systems that comply with fire prevention and fighting regulations to minimize the risk of fire and explosion, affecting labor safety. How to apply fire prevention and fighting regulations in warehouses? Let’s find out more through the article below!

Liên hệ tư vấn và mua hàng

Fire protection standards applicable to warehouses

Warehouses that comply with fire safety safety need to meet the criteria of ventilation, science and neatness. This display arrangement will help limit fires and explosions, and at the same time, when an incident occurs, warehouse operators can easily transport and handle goods in an emergency. Equipping a warehouse shelving system is essential to keep goods in a neat and tidy condition. Always ensure the distance between shelves is up to 0.5m to avoid breakage, damage and comply with fire safety regulations.

quy-dinh-thiet-ke-pccc-nha-kho-xuong-theo-nghi-dinh-79-pccc-2

Fire protection standards applicable to warehouses

Fire prevention regulations for general warehouses

  • For common warehouses, to ensure fire safety, it is necessary to install equipment such as 2-3 fire extinguishers, fire alarms, fire alarm lights,…
  • Build an escape route and plan for the worst possible situations.
  • If a business rents a warehouse or premises from a third party, it is necessary to determine who is responsible for fire prevention and control, is it the warehouse owner or the renting unit? From there, that unit is required to strictly implement fire prevention regulations.
  • All common warehouses absolutely do not store, circulate and use banned chemicals that cause fire or explosion. Substances such as gas, gasoline, alcohol and other chemicals require a license to be stored in a warehouse.
  • When danger occurs, notify the fire police at 114 or the nearest police station, promptly evacuate people and conduct fire fighting.
Doanh-nghiệp-cần-lắp-các-tiêu-lệnh-PCCC-trong-nhà-kho-scaled

Equip fire protection equipment in the warehouse according to regulations

Fire protection regulations for cold storage

  • Principles of fire protection in cold storage are similar to regular warehouses. The only difference is that operating the air conditioner requires a healthy person to do it. Especially in the process of loading solvents, the machine needs to be done carefully and closely supervised by at least 2 people during this stage.
  • When fire or explosion problems occur, you should immediately contact the fire prevention team or the nearest police agency in your ward to coordinate to put out the fire as soon as possible.

>> See more: European standard warehouse shelf production process

Arrange factory goods according to fire protection standards

Goods need to be classified on separate shelves. Use the Selective racking system with mesh panels and tole trays for safe fire protection in the warehouse. This is the minimum that warehouses must handle to avoid much loss of life and property.

ke-selective-2

Selective racking system supports fire protection in warehouses

It is necessary to fully equip the warehouse with fire prevention and fighting equipment. Each floor/floor has a minimum of 2-3 tanks. With a smaller warehouse rental area of ​​100m2, at least 2 fire extinguishers are also required.

When designing a warehouse, attention should be paid to arranging emergency doors or stairs in case of fire or explosion.

Choosing prime locations to produce and circulate goods is now more and more popular. Because currently, many fires and explosions originate from warehouses due to failure to properly comply with fire prevention and fighting regulations for warehouses and factories, leading to a lot of human and property damage. Therefore, the standards in Decree 79 need to be enforced more strongly.

VietPOSRack is proud to be the unit that ensures the safety of fire prevention and fighting regulations for warehouses. VietPOSRack always operates according to the standards listed above. At the same time, always supervise and monitor warehouse operations to respond promptly if any fire incidents occur in the warehouse. For further information, please contact: 0796700777 for advice and guidance on fire protection for your warehouse.

More information

Radio Shuttle Rack – Automatic Shuttle Rack Optimizing Bulk Storage Warehouses

A 5,000m² beverage warehouse in Long An operates 40,000 pallets/month but forklifts only run 3-5 [...]

Push Back Rack – LIFO Rack System Optimizing Cold Storage Space

Push Back Racking is a high-density storage solution based on the LIFO principle, helping to [...]

Double Deep Rack – Solution to Increase Warehouse Density by 2x

Double Deep Rack helps increase storage density by 40-60% compared to Selective racking by eliminating [...]

A Cantilever Rack is a cantilever rack for extra-long, extra-heavy loads.

Cantilever Rack (cantilever rack, support arm rack) is the optimal solution for long goods such [...]

What is an automated rack? Overview of automated warehouse systems

Automated racking is a storage system that combines shuttle robots, AGV, AS/RS, and WMS software [...]

RFID in industrial warehouse management 2026: Realtime solutions for 3PL

The 3,000m² warehouse of Tan Phat Logistics Co., Ltd. in Binh Duong used to lose [...]

Apartment Storage Locker Solutions: Developer’s Procurement Guide

A complete procurement guide for residential developers specifying tenant storage locker systems. Learn how to [...]

Tenant Storage Locker Systems: B2B Buyer’s Guide 2025

Complete guide to tenant storage locker systems for apartment developers and property managers. Compare wire [...]

Sales office system in Can Tho, Ho Chi Minh, Dong Nai, Nha TrangDa Nang, Hanoialways ready to serve you.

0905295337